Fan motor
25/11/2025
1, Details of Inspection: – Sound audibility check,- Insulation resistance measurement 2,Inspection Method:Audible inspection 500 V mega. 3, Criteria <Standard>:- There should be no abnormal sound generation, – The resistance value should be 1 MΩ or more 4, Details of Maintenance:When a bearing sound is loud, replace the bearing,- When the resistance value is 1 MΩ […]